Monitoring Devices

Voltage Monitoring

VOLTAGE MONITORING SERIES SM 800

  • LCD Display with Green Back light
  • Can be configured for 3 Phase 3 Wire and 3 Phase 4 Wire
  • Password Protection
  • Log of 5 previous faults for better monitoring
  • Selectable Over Voltage/ Under Voltage, Asymmetry, Phase Loss, Phase Sequence, Over Frequency/Under Frequency
  • Fail safe/ Non-Fail safe relay output
  • Two Separate Relay outputs with independent Programming

VOLTAGE MONITORING SERIES SM 175

  • Compact 17.5 mm Wide
  • Multi-Voltage: Three Phase 3 Wire @ 208-480 VAC or Three Phase 4 Wire @ 120-277 VAC
  • Can be configured for 3 Phase 3 Wire or 3 Phase 4 Wire system
  • Protection against Phase loss, Phase Sequence, Phase Asymmetry, Under Voltage & Over Voltage
  • Selectable Under Voltage / Over Voltage, Asymmetry and Phase Sequence
  • LED Indication for all Faults & for change in dip switch settings during runtime for better security
  • Adjustable ON/OFF Time Delay in seconds / minutes
  • 1 C/O Configuration

VOLTAGE MONITORING SERIES SM 175

As the name suggests, this is an Electronic Timer with staircase like design. This timer switch has multiple features, let’s take a look to understand better.

  • Compact 17.5 mm Wide
  • Protects against Phase Loss, Phase Reversal & Phase Asymmetry
  • Multi-Voltage: Three Phase wire @ 208 – 480 VAC
  • Selectable Under Voltage / Over Voltage & Asymmetry
  • LED Indication for all Faults & for change in settings during run time for better security
  • Adjustable Time Delay
  • 1 C/O Configuration

VOLTAGE MONITORING SERIES SM 301

  • Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance
  • No auxillary supply needed
  • Voltage sensing principle
  • 1 C/O & 2 C/O Configurations
  • Designed to meet Industrial and Agricultural segment applications

VOLTAGE MONITORING SERIES SM 500

  • Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance
  • Can be configured for 3 Phase 4 Wire or 1 Phase system
  • Selectable Over/Under voltage trip level
  • Selectable Time Delay
  • LED indications for power and fault conditions
  • Voltage sensing principle
  • 1 C/O or 2 C/O Configuration

VOLTAGE MONITORING SERIES SM500 – NEUTRAL LOSS PROTECTION

  • Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance
  • Can be configured for 3 Phase 4 Wire or 1 Phase system
  • Selectable Over/Under voltage trip level
  • Selectable Time Delay
  • LED indications for power and fault conditions
  • Voltage sensing principle
  • 1 C/O or 2 C/O Configuration

VOLTAGE MONITORING SERIES SM 501

  • Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance.
  • Suitable for 3 Phase 3 Wire system.
  • Selectable Under Voltage / Over Voltage Trip level.
  • Selectable Time Delay.
  • Models for Selectable Phase Asymmetry.
  • LED indications for power and fault conditions.
  • Voltage sensing principle.
  • 2 C/O configuration.

THREE PHASE INDICATOR

  • Compact 17.5 mm Wide
  • Available for Single, Two and Three Phase indications
  • Choice of four colors
  • LED technology for long life
  • Integrated front product labeling

CURRENT MONITORING (CURRENT RELAY)

CURRENT MONITORING SERIES CMR – CURRENT CONTROL

  • Protection against Overload, Phase Loss, Phase Reverse and Phase Unbalance faults
  • A wide range of sensing current: 1A – 45A
  • Models for 1 Phase and 3 Phase systems
  • Auto / Manual Reset selection
  • Fail-safe protection
  • Inverse time model with underload, locked rotor protection and selectable trip class
  • Definite time model with underload and selectable start and trip time

EARTH LEAKAGE RELAY SERIES CMR

EARTH LEAKAGE RELAY SERIES CMR

  • Flush Mounting Version 96×96 mm with Digital Seven Segment Display
  • Monitors, Detects and Protects Power systems from Earth Leakage Fault (Type ‘A’ & ‘AC’)
  • A wide range of selectable Earth Leakage Current: 30 mA – 30 A
  • Configurable Earth Leakage Trip time: 0 – 10 s
  • Wide Auxiliary Supply Range: 110 – 240 VAC / DC
  • Nano Crystalline CBCT measures the leakage current to the highest accuracy
  • Instantaneous Trip for 5 times of set value of Leakage current
  • Test feature to check complete product functionality
  • LED Indication for Relay Status, Earth Leakage Fault & Alarm Condition
  • Manual / Remote Reset feature
  • Continuous Scrolling display for Set Current and Set time
  • 1 C/O (Alarm Relay) + 1 C/O ( Fault Relay)
  • RS 485 Communication

EARTH LEAKAGE RELAY 30MA-30A

  • Monitors, Detects and Protects Power systems from Earth Leakage Faults
  • Wide range of selectable Earth Leakage Current: 30 mA – 30 A
  • Configurable Earth Leakage Trip time: 0 – 10 s
  • Wide Auxiliary Supply Range: 110 – 240 V AC / 110 V DC, 220 – 415 V AC / 220 V DC
  • Instantaneous Trip for 5 times of set value of Leakage current
  • Test feature to check complete product functionality
  • LED Indication for Relay status, CT open, Earth Leakage fault & Test/Reset switch feature
  • Manual / Remote Reset feature
  • 1 C/O + 1 NO Relay Output

FREQUENCY MONITORING

FREQUENCY MONITORING SERIES PD 225

  • Wide Auxiliary Supply Voltage Range: 110 – 240 VAC, 220 – 440 VAC
  • Models for Over Frequency and Under/Over Frequency Monitoring
  • Monitors frequency of three signals – Sine, Square & Triangular
  • Model for Frequency Limit Control: 5 Hz to 135 Hz
  • Wide Signal Input Voltage: 15 to 500 VAC
  • Adjustable Relay status in healthy or unhealthy condition using DIP switch “ET” (Energize to Trip) or “DT” (De-energize to trip.)
  • Ease of Frequency setting with simple Addition & Subtraction
  • LED indications for healthy, unhealthy & no signal conditions

TEMPERATURE MONITORING

PTC THERMISTOR RELAY SERIES PD 225

  • Monitors and Protects Motors with Integrated PTC Resistor sensors
  • Protection against Over heating for Heavy Duty Load, High Switching Frequency, High operating temperature & Insufficient cooling conditions
  • Wide Auxiliary Supply Voltage: 24 VAC/DC, 110 – 240 VAC & 220 – 415 VAC
  • LED Indications for Healthy, Unhealthy, Sensor Open/Short conditions
  • 1 C/O & 2 C/O Configuration
  • Reset Options: Auto, Manual and Remote

PTC THERMISTOR & SINGLE PHASING PREVENTER SERIES PD225

  • Thermistor Relay combined with Protection against Phase Sequence, Phase Loss & Phase Asymmetry Faults.
  • Monitors and Protects Motors with Integrated PTC Resistor sensors.
  • Protection against Over heating for Heavy Duty Load, High Switching Frequency, High operating temperature & Insufficient cooling conditions.
  • LED indications for Healthy, Unhealthy, Sensor Open/Short and Phase Sequence fault conditions.

EQUIPMENT ROOM TEMPERATURE CONTROL RELAY

  • Provides protection against variations of the ambient temperature (min/max) in equipment or lift rooms.
  • Suitable for use in Traction and Hydraulic Lift Types.
  • Supports an External sensor module.
  • LED Indication for Relay Trip & Power ON.

LEVEL MONITORING

LIQUID LEVEL CONTROLLER

  • Fully Automatic operation enabling both draining and filling simultaneously with a single device.
  • Adjustable sensitivity level from 1k to 200k Ohm.
  • Includes provision for Manual start.
  • Protects submersible pumps against dry running and prevents overfilling.
  • Enables maximum utilization of incoming liquid (eg. water) supply.
  • Specially designed corrosion and shock resistant sensors to ensure trouble-free operation.